• New Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCB
  • New Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCB
  • New Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCB
  • New Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCB
  • New Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCB
  • New Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCB

New Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCB

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Oil-immersed Type
Installation: Fixed
Structure: ELCB
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Basic Info.

Model NO.
JLID
Poles Number
2
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
VDE, ISO9001-2000, CE, CB, CCC
Transport Package
60PCS/CTN
Specification
int′l standards
Trademark
OEM
Origin
China
HS Code
8536200000
Production Capacity
1000PCS/Week

Product Description

Application:

ID RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage.The RCCB is mainly suitable for use in varieties of plants and enterprises, building construction 1 phase 230V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC pulse system.

Specifications:

Number of Poles 1P+N, 3P+N
Rated Current (A) 16, 20, 25, 40, 50, 63
Rated Residual Operating Current (IΔn)(mA) 30, 100, 300, 500
Rated Voltage (V) AC 230/400
AC 400/415
Residual Operating Current Scope 0.5IΔn~IΔn
Residual Current Off-time ≤0.3S
Short Circuit Capacity (Icu) 6000A
Endurance 4000
Protection Degree IP20

Normal Operation and Mounting Requirement

? Circumstance temperature -5°C~+40°C, average temperature not exceeding 35°C.
? Altitude above sea level less than 2000m.
? Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
? Installation class II or III.
? Pollution class II.
? Installation method DIN Rail mounting type.
? The external magnetism shall not be more than 5 times of terrestrial one.
? Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.
New Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCBNew Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCBNew Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCBNew Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCB

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category

Supplier Homepage Products Breakers ELCB New Design Jlid 2pole 2p 100AMP 6A 16A 20A 25A 32A 40A 63A 80A 100A 10ka RCCB/RCD Circuit Breaker 10AMP RCCB