Basic Info.

Model NO.
BH-0.66
Insulating Medium
Insulating Paper
Installation
Busbar Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Paper Box Packaging
Specification
standard sizes
Trademark
SPR or OEM
Origin
Wenzhou
HS Code
8504311000
Production Capacity
1000PCS/Week

Product Description

BH-0.66(LMK-0.66) series molded case insulation current transformers are all busbar type, and are mainly used for indoor . The BH-0.66 series CTs are used in  rated frequency is 50Hz & rated voltage 0.66KVAC circuit to check current , measure the power and relay protection.

Construction :
This series current transformer core is a ring core or a rectangular wound core, the secondary coil is insulated by a rubber case, and there is mounting hole in the bottom for users to install and use, and the middle window hole is used for Bus wire pass or soft cable winding .

Working environment :
  1. Altitude: <1000m
  2. Environment temperature: -5~40ºC
  3. Relative humidity(RH): ≤85% (when 20ºC)
  4. Installation place : There should be no contamination that seriously affects the insulation of the transformer and also without substances that causes corrosion and explosion.
Technical parameters :
  1. Rated voltage :660V
  2. Rated frequency :50HZ
  3. Rated secondary current: 5A
  4. Rated first current: 5-5000A
  5. Rated output : 2.5VA,5VA,10VA,20VA,40VA;
  6. Accuracy classes: 5 , 3 ,1 , 0.5 , 0.5S , 0.2 , 0.2S
  7. Insulation: Primary winding to secondary winding and secondary winding to ground can withstand power frequency voltage 3KV for 1 min.


Installation tye and maintenance
  1. Installation type : Horizontal and vertical installation both available 
  2. When the transformer is running, it is forbidden to open the secondary winding to prevent the high voltage from causing
  3. damage to the equipment and the human body.
  4. For counting : the small current ratio to get the using turn number of the current transformers. The bus bar cross the window
  5. hole one time , it is one turn , if bus bar cross the window hole 2 times it is 2 turns , and so on .

    Multi-times through core current ratio and through core turns
150A turn Current ratio(A) 150/5 75/5 50/5 30/5 25/5 15/5
Through core turns 1 2 3 5 6 10
200A turn Current ratio(A) 200/5 100/5 50/5 40/5 20 10
Through core turns 1 2 4 5 10 20
 
  1. For monitoring ,the small current ratio (30-100/5) current transformer through core is one turn , accuracy level 3 or 5.
  2. The cross-sectional area of the copper wire connected to the secondary instrument and the relay should be ≥ 2.5mm² .
  3. The way to judge dotted terminals is : when the first current flows from P1 to P2, the secondary current will flow back
  4. through the external circuit of S1 to S2.

Dimension Table:
Part no. H W B L1 Window size Housing Dimension
m n
BH-0.66-30 I Class0.5 79 60 39 28 Figure (4) Figure (1)
BH-0.66-30 I Class0.2 98 77 45 42 Figure (5)
BH-0.66-40 I 98 77 45 42 Figure (6)
BH-0.66-50 I 98 82 40 50 Figure (7)
BH-0.66-60 I 127 99 44 41 Figure (8)
BH-0.66-40 II 103 76 45 45 42 31 Figure (2)
BH-0.66-50 II 106 87 45 54 52 31
BH-0.66-60 II 111 99 46 42 62 31
BH-0.66-80 II 118 119 45 60 83 32
BH-0.66-100 II 122 140 50 74 102 32
BH-0.66-120 II 154 167 48 54 122 52
BH-0.66-125 II 175 178 60 68 127 61 Figure (3)
BH-0.66-60 III 139 100 45 43 62 52 Figure (2)
BH-0.66-80 III 148 118 45 61 82 52
BH-0.66-100 III 155 148 45 78 101 52
BH-0.66-125 III 180 170 45 78 125 52

Bh-0.66 Series Current TransformersBh-0.66 Series Current TransformersBh-0.66 Series Current TransformersBh-0.66 Series Current TransformersBh-0.66 Series Current TransformersBh-0.66 Series Current Transformers

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now