Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
147802.18 USD
Plant Area
1000 square meters
Management System Certification
ISO 9001, ISO 9000, ISO 14000
  • Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)
  • Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)
  • Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)
  • Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)
  • Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)
  • Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)
Find Similar Products

Basic Info.

Model NO.
BVAFD-63
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
ELCB
Poles Number
2
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
CE, CCC
Transport Package
Paper Box Packaging
Specification
50X45X40CM
Trademark
OEM
Origin
Wenzhou
HS Code
8536200000
Production Capacity
1000PCS/Week

Product Description

BVAFD-63 Arc Fault Circuit Interrupter(AFCI) is a new technology for circuit protection. Its main function is to detect and
distinguish the dangerous ground arc fault, parallel arc fault and series arc fault, drive the device of current disconnection
in time to avoid the occurrence of electrical fire.

When an electrical fault occurs, due to the low current intensity, which is lower than the over-current protection installation
setting value widely installed in the current system, especially in the low-voltage distribution field, the installation of a fault
arc breaker at the distribution line terminal can timely detect the arc and cut off the circuit, effectively reducing the loss
caused by the arc.

The fault arc breaker is an intelligent circuit protector, an integrated design of MCB and RCB, which can detect and identify
the fault arc in the circuit and the arc in normal operation. To prevent fire hazard caused by faulty electric arc due to poor contact
and insulation in electrical circuit.

It is a circuit protection device integrating fault arc protection, overload protection, short circuit protection, surge suppression
and leakage protection. 

 

1. Applications:

The fault arc breakers are mainly installed in the distribution box of the terminal distribution system, and can also be installed
in the control circuit units of home and office, all kinds of large supermarkets, department stores, hospitals, airports, textile mills,
warehouses, oil depots, oil refineries, entertainment places, hotels, oil pipelines and so on.

Wherever electricity is used, the device must be installed and used widely for electrical fire protection. 

2. Features: 

*Protection against arc fault, overload and short circuit, the function of isolation
*High short circuit capacity
*Pin/fork type busbar terminal connecting
*18mm DIN rail mounting and screw mounting
*Full range accessories are available.

*Flame-redardant: PA66 nylon material.

*Protection degree: IP20.

*Enduring termperature: 30°C.

*Breaking Capacity: 6KA.

   

3. Technical Data: 

Type
BVAFD-63  
Poles
1P+N/2P
Rated current
6, 10, 16, 20, 25, 32, 40, 50, 63A
Rated voltage
AC 230V/AC 110V 50/60Hz
Characteristic capacity
4.5KA/6KA
Electrical life
6000times
Impact Withstand Voltage(Uimp)
4kV
Tropicalizes
Treatment 2
Curve
B,C,D
Certificate
CE, GB
Standards
IEC 60898-1
Rated impulse withstand voltage
4.5kA/6kA
Connection terminal
Screw terminal / Pillar terminal with calmp
Connection capacity
Rigid conductor up to 25mm²
Fastening torque
2.0Nm
Installation
On symmetrical DIN rail 35mm / Panel mounting
Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)Model No. Bvafd-63 Arc Fault Leakage Protection Circuit Breaker (Fire Prevention AFCI Lekage Spark Dector)