Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | RS485 Software |
Still deciding? Get samples of US$ 81/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
In the construction of smart grid, intelligent power distribution is an indispensable and important component. The intelligent features of intelligent power distribution can not only greatly reduce the difficulty of grid operation management, but also control and relieve personnel. Stress is especially important.
The products realize accurate display of current, voltage and power. Let the current change, voltage fluctuations, load power consumption more clearly. It is equipped with a power statistics function, supports billing amount setting, quickly queries historical data, and controls power consumption status.
With an impeccable protection mechanism, it provides peace of mind protection. The circuit breaker is equipped with a threshold protection setting. When the electrical parameter in the line exceeds the set value, the product immediately enters the protection state. Structurally, the thermal overload protection is firm and the agile response of the transient protection upholds all the features of the original circuit breaker. Powerful leakage protection function, extremely fast tripping action, effectively protect personal safety. And through sharing, the distribution of permissions and multi-channel control.
Functions:
1. Remote control switch | 2. Manual on/off | 3. Overload protection | 4. Short circuit protection |
5. Mechanical interlock | 6. Voltage acquisition | 7. Currentcollection | 8. Power acquisition |
9. Temperature gathering | 10. Timing action setting | 11. Countdown action setting | 12. Child lock protection |
13. Arrearstrip setting | 14. Historical Power query | 15. Reverse power statistics | 16. Zero setting of electric quantity |
17. Voltage peak recording function | 18. Current threshold | 19. Over voltage threshold | 20. Undervoltage threshold |
21. Temperature threshold |
Executive Standard: | GB/T10963.1, GB/T16917.1, CQC1149-2020 |
Rated Voltage: | AC220V |
Rated Frequency: | 50/60Hz |
Pole: | 2P |
Operating Temperature: | -50°C to +65°C |
Frame Current: | 125A |
Rate Current: | 10A 16A 20A 25A 32A 40A 50A 63A |
Rated Impulse Withstand Voltage: | 6000V |
Instantaneous Tripping Form: | Curve C |
Control Level Voltage: | AC220V |
Rated Short-circuit Breaking Capacity: | Icn=6KA; Ics=6KA |
Mechanical Life: | ≥10,000 times |
Electrical Lfe: | ≥6,000 times |
Precision: | Level 1 |
Power Consumption: | ≤2W |
Voltage: | 0.1V |
Current: | 0.001A |
IP Grade: | IP20 |
Unit Price (Ex Works) | 2P 220V 50/60Hz 10A, 16A, 20A, 25A, 32A, 40A $80.85/PC 2P 220V 50/60Hz 50A, 63A $82.85/PC |