Secured Trading Service

Secured Trading Service

What is STS?

STS is an escrow service that protects both buyers and suppliers. Funds are held securely by Made-in-China.com until order terms (e.g., delivery, quality) are fulfilled

Key Advantages

Payment Protection:
Your payment is only released to the supplier after you confirm satisfactory delivery.Suppliers receive payment only upon your approval.
Dispute Resolution:
If issues arise (e.g., quality discrepancies, shipping delays), our team mediates and facilitates resolutions based on evidence.
Flexible Payment Options:
Supports credit cards (Visa/MasterCard), PayPal, Apple Pay, Google Pay, many local payment methods and T/T (bank transfer).

S-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO Breaker

Still deciding? Get samples of $ !
Request Sample
Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Online Trading Protection
Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Manufacturer/Factory & Trading Company
Gold Member Since 2006

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (15)
  • S-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO Breaker
  • S-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO Breaker
  • S-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO Breaker
  • S-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO Breaker
  • S-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO Breaker
  • S-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO Breaker
Find Similar Products

Basic Info.

Model NO.
TORD1S
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
ELCB
Poles Number
2p, 4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Transport Package
50PCS/CTN
Specification
Int'l Standards
Trademark
OEM
Origin
Wenzhou
HS Code
8536200000
Production Capacity
1000PCS/Week

Product Description

S-type Time-delay Residual Current Device (S-type Time-delay Residual Current Circuit Breaker)
 

Descriptions:

Model Name TORD1S-63
Model Electromagnetic type
Residual Current characteristic  AC
Rated current(A)  63A
 Rated residual operating current (A)  0.1, 0.3
 Rated conditional short-circuit current inc  6kA
 Tripping duration  time delayed
 Electro-mechanical endurance  ≥20000 cycles
 Connection terminal  Screw terminal Pillar terminal with clamp
 Fastening torque  2.0 Nm

Tips: S type time delayed electromagnetic RCCB

 

S-Type RCD is a sinusoidal residual current device incorporating a time delay.

 

It can be installed upstream from a Type AC RCD to provide selectivity. A time-delayed RCD cannot be used for additional protection.

 

Where circuits have more than one RCCB, a time delayed unit can be used 'upstream' to allow the RCCBs or RCBOs further down the circuit to
trip first and avoid nuisance tripping of the whole circuit.


The TORD1S series 6kA Type-S 1P+N & 3P+N  Time-delay RCD (Residual Current Device) is the perfect solution for a complete protection against
over-current  and earth fault currents. In two modules width (80mm) the series ensure, at any time and under any condition, the safety of people, facilities
and related equipment.

Forward and reverse wiring is permitted.
The top and bottom can be connected to a busbar with a cross section of up to 16 mm² and to wires with a cross section of up to 25 mm².
Leakage indicator (blue/red sign inside the small window) makes it easy to check the source of product faults and reduces maintenance time.

Enhanced Safety Features:
This product provides overload and short circuit protection to ensure safe and reliable operation of circuits in domestic, commercial and residential applications.

HIGH QUALITY CONSTRUCTION:
With high quality materials and construction, this miniature circuit breaker provides reliable performance and durability that meets the expectations of demanding users.

Versatile Design:
The air switch is designed for both domestic and commercial use, making it a versatile solution for a wide range of electrical applications, including high traffic areas or areas with high electricity demand.

Functions:
1. Protection of persons against electric shock by direct contact (30mA)
2. Protection of installations against the risk of fire by direct contact (300mA)
3. Protection of persons against electric shock by indirect contact (100mA-300mA)

Operation Princples:
Protetion from electric shocks by direct contact
1. Protection of persons against electric shock by direct contact (30mA)
2. Protection of installations against the risk of fire by direct contact (300mA)
3. Protection of persons against electric shock by indirect contact (100mA-300mA)

Technical Data:
  Type TORD1S-2P TORD1S-4P
Standards IEC/EN 61009-1, IEC/EN 61009-2-1;  
Certificate CE, RoHS
Country of origin Wenzhou  
Electrical features Type (wave form of the earth leakage sensed) Type S
Number of poles 1P+N 3P+N
Rated current In A 6, 10, 16, 20, 25, 32, 40, 50,
63 A
6, 10, 16, 20, 25, 32, 40 50, 63A
Rated sensitivity IΔn mA 100, 300 mA 100, 300 mA
Rated voltage Ue V 220/230/240 V 380/400/415 V
Operating time Type A / Type AC Instantaneous
  Type A[S] 15 ms delay
  Type A[G] 40 ms delay
Insulation voltage Ui V 500V AC
Overvoltage category III
Pollution degree 2
Operating voltage of circuit test V 187 - 264 V 230 - 485 V
Rated frequency Hz 50/60 Hz
Rated breaking capacity acc. to IEC/EN 61009-1 Icn A 10,000 A
Rated breaking capacity acc. to IEC/EN 64947-2
(Only referring to short circuit test)
Icu A 15,000 A
Ics A 7,500 A (50%Icu)
Rated residual breaking capacity
acc.to IEC/EN 61009-1
IΔm A 6000 A
Rated impulse withstand voltage (1.2/50) Uimp kV 4 kV
Dielectric test voltage at ind. freq. for 1 min. kV 2.5 kV (50/60Hz, 1 min.)
Thermomagnetic release - characteristics Characteristics B: 3In - 5In
Characteristics C: 5In - 10In
Energy limiting class acc. to EN 61009-1 3
Surge current resistance (wave 8/20) A 3000 A
Mechanical features Housing     Insulation group I - II, RAL 7035
Toggle     Insulation group II, RAL 5017
Test button     Insulation group II, RAL 2000
Contact position indication     Green / Red window
Earth fault trip indication     White window
Electrical life Operations 4000 cycles
Mechanical life Operations 10000 cycles
Protection degree acc. to EN 60529 Housing IP4X
Terminals IP2X
Shock resistance acc. to IEC/EN 60068-2-27     25g - 2 shocks - 13ms
Vibration resistance acc. to IEC/EN 60068-2-6     0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
Environmental conditions (damp heat) acc. to IEC/EN 60068-2-30   °C/RH 28 cycles with 55°C/90-96% and 25°C/95-100%
Reference temperature for setting of thermal element   °C 30 °C
Ambient temperature (with daily average ≤ +35 °C)   °C -25… +40 °C
Storage temperature   °C -40… +70 °C
Installation Terminal type Twin-purpose terminal (lift / open-mouthed)
Terminal size for cables bottom / top mm² 25/35 mm²
Terminal size for PIN busbar bottom / top mm² 10/16 mm²
Terminal size for FORK busbar bottom / top mm² M6 - 10/16 mm²
Solid /stranded wiring 1x 1mm² - 35mm²
2 x 1mm² - 16mm² *
Flexible wires with or without ferrules 1x 1mm² - 25mm²
2 x 1mm² - 10mm² *
Tightening torque bottom / top 2 Nm
Stripping length of the cable 10mm
Mounting On DIN rail EN 60715 (35mm)
by means of mounting clip
Mounting position Any
Connect from Top/bottom terminals
Dimensions (H x W x D) mm 90 x 36 x 72 mm 90 x 72 x 72 mm
Weight kg 0.19 kg 0.42 kg
Packing Packing A
(Individual box)
Quantity pieces 1 1
Dimension (H*W*D) mm 90*40*80 mm 90*78*81 mm
Weight kg 0.2 kg 0.43 kg
Packing B (*A)
(Middle box)
Quantity pieces 6 3
Dimension (H*W*D) mm 255*95*91.2 mm 242*98*89 mm
Weight kg 1.3 kg 1.3 kg
Packing C (*B)
(Master carton)
Quantity pieces 60 30
Dimension (H*W*D) mm 510*275*200 mm 520*255*200 mm
Weight kg 14.5 kg 14.5 kg
Combination with
auxiliary elements
Auxiliary contact NA (yes) NA (yes)
Allarm contact NA (yes) NA (yes)
Shunt trip NA (yes) NA (yes)
Auxiliary contact for bottom fitting NA (yes) NA (yes)
Undervoltage release NA (yes) NA (yes)
Overvoltage release NA (yes) NA (yes)
Motor operating device NA (yes) NA (yes)

S-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO BreakerS-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO BreakerS-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO BreakerS-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO BreakerS-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO BreakerS-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO BreakerS-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO BreakerS-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO BreakerS-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO BreakerS-Type Time-Delay Residual Current Device (S-Type Time-delay RCD) , S-Type Time-Delay RCBO Breaker


 