• Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)
  • Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)
  • Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)
  • Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)
  • Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)
  • Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)

Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: ELCB
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Basic Info.

Model NO.
DZ47LE
Poles Number
1p+N, 2p, 3p, 3p+N, 4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CCC
Transport Package
Export Packaging
Specification
55X45X85CM
Trademark
TIANZE or OEM
Origin
Wenzhou
HS Code
8536200000
Production Capacity
1000PCS Per Week

Product Description

1.Applications:

DZ47LE is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz,rated voltage 1 phase 230V and 3 phase 400V,rated current up to 63A.When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value,the RCBO can cut off the power within the time of 0.1s automatically to protect the personal safely and preventing the equipment from the fault resulted by the residual current.With this function,the RCBO can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions.It conforms to IEC61009 standard.

Circumstance temperature -5 ºC~+40 ºC,average temperature not exceeding 90% at 25ºC

Altitude above sea  level less than 2000m

Humidity not exceeding 50% at 40 ºCand not exceeding 90% at 25 ºC

Installation class II or III

pollution class II

Installation method DIN Rail mounting type

The external magnetism shall not be more than 5 times of terrestiral one.

Product shall be installed vertically at the place where there shall be no severe impact and vibration.The product is switched on when the handle is at upper

2.Main technical data:

Number of Poles

1P+N,2P,3P,3P+N,4P

Rated Current(A)

6,10,16,20,25,32,40,50,63

Rated non operating current(mA)

30,100,300,500

Rated non operating(IN)(mA)

≤0.5In

Rated Voltage(V)

220/380

Tripping curve

C,D

Type

Electronic

Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)Dz47le C45le 2p Earth Leakage Circuit Breaker with Over Current Protection (DZ47LE ELCB)