• Jdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage Transformer
  • Jdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage Transformer
  • Jdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage Transformer
  • Jdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage Transformer
  • Jdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage Transformer
  • Jdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage Transformer

Jdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage Transformer

Application: Electronic, Instrument, Position Sensor, Audio, Lighting
Type: Voltage Transformer
Phase: Single
Operation Condition: Outdoor
Usage: Protection, Measurement
Winding Form: Multilayer Honeycomb Type
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Basic Info.

Model NO.
JDZW-10(6)R
Insulating Medium
Insulating Oil
Installation
Active Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Paper Box Packaging
Specification
50X45X53CM
Trademark
TIANZE or OEM
Origin
Wenzhou
HS Code
8504311000
Production Capacity
10000PCS/Week

Product Description

JDZW-10(6)R Outdoor Voltage Transformer/ 10kV voltage transformers is suitable for JDZW-10R fully enclosed in sulated voltage transformer(hereinafter referred to as transformer er). The Single Phase Voltage Transformer is outdoor device, it is built-in with fuse to be used in power system with rated frequency of 50Hz/60Hz and rated voltage of 10KV for electrical measurements, protection and power supply.
 

Working Conditions 
1.System grounding method - Single Phase Voltage Transformer
Neutral point non-effective grounding system

2.Standard- 10kV Voltage Transformer

No. Name   Unit Parameter
1 Ambient temperature(outdoor) Maximum temperature ºC 40
Minimum temperature ºC -30
Maximum daily temperature difference K 30
2 Altitude m ≥1500
3 Solar radiation intensity W/cm2 0.1
4 Ice thickness  mm 10
5 Wind speed and wind pressure m/sPa 34/700
6 Maximum wind speed(from the ground heigh 10M, to maintain the average maximum of 10min m/s 35
7 Humi dity Average relative humidity % ≤95
Average monthly relative humidty ≤90
8 Earthquake resistant capacity Horizontal acceleration g 0.3
Ground vertical acceleration 0.15
Safety factor / 1.67
Technical Parameters
Type Rated frequency(Hz) Rated voltage ratio (V) Accuracy class Rated output(VA) Ultimate output(VA) Rated insulation leve(kV)
JDZW-6R 50-60 6000/220 3 500 1000 7.2/32/60
JDZW-10R 50-60 10000/220 3 500 1000 12/42/75
JDZW-6R 50-60 600/100/220 0.5/3 30/500 1000 7.2/32/60
JDZW-10R 50-60 10000/100/220 0.5/3 30/500 1000 12/42/75
Jdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage TransformerJdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage TransformerJdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage TransformerJdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage TransformerJdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage TransformerJdzw-10 (6) R Cost-Effective 10kv Single Phase Outdoor Voltage Transformer